Capstracteesscapstract:2611.00055

Electrical Engineering and Systems Science > Systems and Control

Title:Regulation of Remote Meeting Temperature Using an Unoccupied Conference Room

Abstract:

We study a building controller that regulates the temperature of a fully remote meeting by cooling an assigned, unoccupied conference room. The controller combines a vocal arousal estimate from the video call with the room air temperature and lowers the room setpoint when this composite meeting-temperature signal is high. A two-state model shows that the remote discussion is uncontrollable from the room HVAC input, although the composite signal responds to cooling. In 1,000 paired simulated meetings, increasing the controller gain from zero to 2 °C per arousal unit reduces the fraction of composite samples above a fixed threshold from 60.69% to 23.63%. The corresponding vocal-channel fraction remains 60.69%, and the latent arousal trajectory is unchanged. Normalized cooling input rises from 4.500 to 5.161 °C, while the mean minimum room temperature falls from 22.000 to 21.410 °C. Removing the room-temperature term from the composite signal eliminates the apparent improvement. An independent vocal channel detects the discrepancy but does not make the remote meeting controllable. The study uses synthetic meetings and an illustrative thermal model.

Comments:4 pages, 2 figures, 1 table; simulation study.
Subjects:Systems and Control (eess.SY); Human-Computer Interaction (cs.HC)
Cite as:capstract:2611.00055 [eess.SY]
 (or capstract:2611.00055v1 [eess.SY] for this version)

Submission history

From: Mara Voss
[v1] Fri, 20 Nov 2026 21:22:50 UTC (117 KB)

Current browse context:

eess
Change to browse by:

Export citation